EcoWater No Regeneration / Control Not Initiating Cycle

Softener does not regenerate at all; no noise or movement at scheduled time and water becomes hard.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect time or regeneration schedule, Power loss or dead transformer, Control board failure, Flow meter not registering usage on demand-initiated models

How to Fix / Troubleshooting

Safety first: This troubleshooting is mostly electrical and programming; no need to open wet components initially. Unplug before removing covers.

Steps to diagnose:

  • 1. Check display and time: Ensure the display is on and the time of day is correct. If the display is blank, test or replace the EcoWater transformer.
  • 2. Verify regeneration mode: Confirm the unit is set to demand-initiated or time clock mode as intended, and that regeneration time is set to an hour when you are not using water.
  • 3. Force a manual regeneration: Press and hold the regen button per the manual. If the valve does not move or the motor does not run, suspect a drive motor or control board issue.
  • 4. Check flow meter: On demand models, verify that water usage is being counted (displayed gallons remaining decrease). If not, inspect and clean the EcoWater turbine/flow sensor.
  • 5. Replace faulty components: If programming and power are correct but the unit will not regenerate, replace the drive motor or main control board as indicated by tests.