Err 0
Fleck Control Board Program Memory Error

Controller display shows “Err 0” and the valve will not start a regeneration cycle automatically.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Corrupted programming in SXT/XTR control, power surge or brownout, failed control board EEPROM, incorrect voltage supply to control

How to Fix / Troubleshooting

Safety first: Unplug the softener’s power supply before opening the control housing. Water is present nearby; keep hands dry and avoid working on live circuits.

  • Power cycle the control: Unplug the Fleck power adapter for 2–3 minutes, then plug it back in. Check if the display returns to normal and if the time-of-day can be set.
  • Verify correct transformer: Confirm the wall transformer matches the valve (typically 24 VAC output, correct amperage). Using the wrong transformer can corrupt or lock the control.
  • Reset to factory defaults: Enter the master programming mode (refer to the specific Fleck model manual, e.g., 5600SXT, 5810SXT, 7000SXT, XTR2). Perform a factory reset, then re-enter hardness, capacity, and regeneration settings.
  • Inspect control board: Remove the front cover, check for burn marks, swollen components, or corrosion on the SXT/XTR board. Reseat the ribbon cable and connectors.
  • If Err 0 persists: The control board memory is likely damaged. Replace the complete control board module with the correct Fleck OEM board for your valve model.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Fleck SXT/XTR Control Board
Check Price on Amazon