Excessive Regeneration Frequency
Fleck softener regenerates too frequently, wasting salt and water.
Advertisements
Possible Causes
Hardness set too high, capacity set too low, incorrect meter size or setting, internal leak through valve causing phantom usage
How to Fix / Troubleshooting
Safety first: No electrical hazards for programming changes; unplug only if opening the control.
- Check hardness setting: Compare programmed hardness to actual tested hardness. Reduce the setting if it is significantly higher than measured.
- Review capacity and reserve: Ensure the programmed capacity and reserve are appropriate for the resin volume and household usage.
- Verify meter size: Confirm the meter size and type in programming match the installed Fleck meter (e.g., 3/4" turbine, 1" turbine).
- Check for internal leaks: If the meter shows flow when no water is being used, inspect for a leaking toilet or faucet, or an internal valve leak (piston/seals) allowing bypass flow.
Advertisements
Repair Difficulty
Easy
2/5