Fleck
No Power to Control
Fleck softener will not power on; display is blank and unresponsive.
Advertisements
Possible Causes
Failed wall transformer, loose power plug, tripped GFCI or breaker, damaged control board power input
How to Fix / Troubleshooting
Safety first: Do not open the transformer; replace it if faulty. Unplug before removing the control cover.
- Check outlet: Verify the outlet has power using another device. Reset any tripped GFCI or breaker.
- Inspect transformer: Ensure the transformer is firmly plugged into the outlet and the low-voltage plug is fully inserted into the Fleck control.
- Measure output: Use a multimeter to check the transformer output (typically 24 VAC). Replace if no or low voltage.
- Inspect control board: If the transformer is good, remove the cover and check for burned components or loose power connectors. Replace the control board if damaged.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Fleck 24V Transformer
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements