Possible Causes

Failed wall transformer, loose power plug, tripped GFCI or breaker, damaged control board power input

How to Fix / Troubleshooting

Safety first: Do not open the transformer; replace it if faulty. Unplug before removing the control cover.

  • Check outlet: Verify the outlet has power using another device. Reset any tripped GFCI or breaker.
  • Inspect transformer: Ensure the transformer is firmly plugged into the outlet and the low-voltage plug is fully inserted into the Fleck control.
  • Measure output: Use a multimeter to check the transformer output (typically 24 VAC). Replace if no or low voltage.
  • Inspect control board: If the transformer is good, remove the cover and check for burned components or loose power connectors. Replace the control board if damaged.