Fleck Brine Line Leak

Water leaks from the brine line connection at the valve or at the brine tank.

Advertisements

Possible Causes

Loose compression fittings, cracked brine line tubing, damaged ferrules, overtightened fittings causing distortion

How to Fix / Troubleshooting

Safety first: Place the softener in bypass and depressurize before working on the brine line.

  • Inspect tubing: Check the entire length of the brine line for cracks, kinks, or pinholes. Replace if damaged.
  • Reseat fittings: Loosen and then retighten the compression nuts at the Fleck valve and brine tank. Ensure the tubing is fully inserted.
  • Replace ferrules or fittings: If the compression ferrules are deformed or the fittings are cracked, replace them with new parts sized for the brine line.
  • Test under pressure: Return the valve to service and observe the connections during a regeneration to confirm no leaks.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Brine Line Tubing and Fittings
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements