GE No Automatic Regeneration

Softener will not start regeneration automatically at the programmed time.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect time or regeneration schedule, Flow sensor not counting usage, Control board clock fault, Unit left in vacation or bypass mode

How to Fix / Troubleshooting

Safety first: No internal work is required for basic checks. Unplug the unit if removing covers.

  • Step 1 – Verify current time: Check that the time of day is set correctly and AM/PM is correct.
  • Step 2 – Check regeneration mode: Confirm the softener is set to demand‑initiated regeneration (if applicable) and that the capacity and hardness are set properly.
  • Step 3 – Confirm flow metering: Run water in the house and verify that the display shows flow and usage accumulating. If not, troubleshoot the turbine sensor.
  • Step 4 – Check vacation/bypass mode: Ensure the unit is not in a vacation or hold mode and that the bypass valve is in service.
  • Step 5 – Test manual regeneration: Start a manual regeneration. If it works manually but never starts automatically, the control board clock or logic is likely faulty. Replace the GE electronic control board.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Electronic Control Board
Check Price on Amazon

We may earn a commission from links on this page.