GE Brine Tank Leak

Water softener is leaking from the brine tank or around the brine well.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Cracked brine tank, Loose brine line fitting, Leaking brine safety float, Overflow from overfilling

How to Fix / Troubleshooting

Safety first: Unplug the unit and close the inlet valve. Mop up standing water promptly to prevent damage.

  • Step 1 – Inspect brine tank walls and bottom: Look for visible cracks or splits. If the tank is cracked, it must be replaced.
  • Step 2 – Check brine line connections: Tighten the nut at the brine valve and at the safety float. Replace ferrules if they are deformed.
  • Step 3 – Inspect safety float: Remove the brine well cover and check the float assembly for cracks or loose seals. Replace the GE brine safety float assembly if leaking.
  • Step 4 – Address overfill cause: If the tank overflowed, see the “Brine tank overfilling” entry to correct the underlying issue.
  • Step 5 – Replace brine tank: If the tank is structurally damaged, install a new GE brine tank compatible with your model.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Brine Tank
Check Price on Amazon

We may earn a commission from links on this page.