E06
Grünbeck Brine Level / Salt Sensor Fault

Display shows E06 and the unit does not measure salt consumption correctly

Advertisements

Possible Causes

Salt level sensor contaminated, Cable to salt sensor disconnected, Sensor corroded by brine, Incorrect sensor mounting height

How to Fix / Troubleshooting

Safety: Disconnect power. Wear gloves and eye protection when working around brine.

  • Locate sensor: On many Grünbeck softeners with automatic salt monitoring, a level sensor is mounted in or above the brine tank.
  • Check wiring: Inspect the cable and connector for corrosion or damage. Clean light corrosion with contact cleaner and reconnect firmly.
  • Clean sensor: Remove the sensor from the brine tank. Rinse with warm fresh water to remove salt crusts. Do not scrape with metal tools.
  • Verify mounting: Ensure the sensor is installed at the specified height and orientation according to the manual so that it correctly detects low salt level.
  • Reset alarm: Reinstall the sensor, reconnect power, and follow the control menu to reset or acknowledge the salt sensor error. If the error persists, replace the salt level sensor.