E17
Grünbeck Automatic Bypass Valve Position Error

Display shows E17 and the unit reports a bypass valve fault

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Bypass actuator jammed, Position switch defective, Scale buildup in bypass channel, Incorrect installation of bypass module

How to Fix / Troubleshooting

Safety: Disconnect power and close inlet valve. Relieve pressure via a tap.

  • Check actuator: Locate the automatic bypass module on the Grünbeck softener. Ensure the actuator is firmly mounted and the linkage is intact.
  • Clean bypass channel: If accessible, remove the bypass module and inspect for scale or debris. Clean with water and an approved descaler, then rinse thoroughly.
  • Test position switch: Check the bypass position sensor or microswitch for correct operation with a multimeter. Replace if faulty.
  • Reinstall correctly: Ensure seals are correctly seated and the module is installed in the correct orientation. After reassembly, restore power and test switching between service and bypass modes.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Automatic Bypass Valve Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements