E08
Hansgrohe Salt Level Sensor / Probe Error

E08 error and the display shows abnormal salt usage or cannot read salt level.

Advertisements

Possible Causes

Contaminated salt level probes, Broken salt level float, Disconnected sensor harness, Heavy salt crust on sensor surfaces

How to Fix / Troubleshooting

Safety: Disconnect power before working inside the brine tank.

  • Access sensor: Remove the brine tank lid. Locate the Hansgrohe salt level sensor or float assembly (often mounted on the brine well or tank wall).
  • Clean sensor: Carefully remove the sensor or float. Rinse with warm water to remove salt crust and sludge. Do not use abrasive tools that could damage the probes.
  • Check movement: If a float is used, ensure it moves freely along its guide rod. Replace if it sticks or is waterlogged.
  • Inspect wiring: Verify that the sensor cable is intact and firmly connected to the control board.
  • Refill with proper salt: Use only high-purity softener salt recommended by Hansgrohe. Avoid rock salt with high impurities that can foul sensors.
  • Test: Reinstall the sensor, restore power, and confirm that the display now shows a realistic salt level. If E08 persists, replace the salt level sensor assembly.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Salt Level Sensor / Float Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements