E17
Hansgrohe Accessory Bus Communication Fault

E17 displayed and the unit reports communication error with external accessories (e.g., remote display or leak sensor).

Advertisements

Possible Causes

Disconnected accessory cable, Damaged communication port on control board, Incorrect accessory addressing, Faulty external module

How to Fix / Troubleshooting

Safety: Disconnect power before plugging or unplugging accessory modules.

  • Check connections: Inspect the communication cable between the Hansgrohe softener and any external modules (remote display, leak detector). Ensure plugs are fully seated.
  • Inspect cable: Look for cuts, abrasions, or crushed sections. Replace damaged cables.
  • Remove accessories: Temporarily disconnect all accessories and power up the softener alone. If E17 clears, reconnect accessories one at a time to identify the faulty module.
  • Port inspection: Examine the control board communication port for bent pins or corrosion. Clean gently if needed.
  • Replace faulty module: If a specific accessory triggers E17 when connected, replace that module.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Accessory Communication Cable / External Module
Check Price on Amazon