Err7
Hellenbrand
Meter Calibration / Flow Count Error
Display shows “Err7” and the unit does not meter water usage correctly (regenerates too often or not at all).
Advertisements
Possible Causes
Incorrect meter size programmed, Wrong pulses-per-gallon setting, Incompatible turbine installed, Control board calibration fault
How to Fix / Troubleshooting
Safety first: Ensure the unit is not in regeneration. You can leave power on to adjust programming.
- Verify meter size: Enter installer programming and confirm the meter size (e.g., 3/4", 1") matches the actual Hellenbrand turbine installed.
- Check pulse setting: Confirm the pulses-per-gallon (or liter) setting matches the turbine specification in the manual. Incorrect values will cause Err7 and improper metering.
- Inspect turbine part number: Compare the installed turbine/flow meter part number to the model’s parts list. Replace with the correct Hellenbrand turbine if mismatched.
- Reset and test: After correcting settings, clear the error (power cycle if needed) and run water while watching the display. Confirm that flow and remaining capacity count correctly.
- Replace control board: If all settings and hardware are correct but Err7 persists, the metering circuit on the board may be defective and require replacement.