Hellenbrand Unexpected / Unsynchronized Regeneration

Softener appears to regenerate at random times, not at the programmed regeneration time.

Advertisements

Possible Causes

Incorrect time-of-day, Power interruptions without backup, Meter immediate regeneration setting, Control board glitch

How to Fix / Troubleshooting

Safety first: Avoid interrupting a regeneration mid-cycle unless necessary; if you must, place the unit in bypass first.

  • Verify clock: Check and correct the time-of-day on the control.
  • Check regen mode: Some Hellenbrand controls can be set to immediate or delayed regeneration. If set to immediate, the unit may regenerate as soon as capacity is exhausted.
  • Review power stability: Frequent outages without a working backup battery can desynchronize the clock. Replace the backup battery or capacitor if needed.
  • Reset control: Perform a factory reset and reprogram. Monitor for a few days to see if random regenerations stop.
  • Board replacement: If behavior persists, the control board may be faulty and require replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements