Hellenbrand
No Regeneration – Control / Programming Fault
Softener does not regenerate at all (no cycling), but display is powered and shows normal time.
Advertisements
Possible Causes
Regeneration mode set to off, Meter not registering flow, Time-of-day or regeneration time mis-set, Drive motor failure preventing cycle start
How to Fix / Troubleshooting
Safety first: Do not force the valve through regeneration steps by hand under pressure unless instructed by the manual.
- Check regeneration mode: Enter programming and verify the unit is set to metered or time-clock regeneration, not “off” or vacation mode.
- Verify clock and regen time: Ensure the time-of-day is correct and the regeneration time is set to a future off-peak hour.
- Confirm meter operation: Run water at a faucet and check that the display shows flow and remaining capacity decreasing. If not, troubleshoot the turbine/flow meter.
- Initiate manual regeneration: Press and hold the regen button to start a cycle. If nothing happens, suspect a failed drive motor or control board output.
- Repair as needed: Replace the turbine/flow meter if not counting, or the drive motor/control board if the valve will not move into regeneration.