E04
Idrobase
Flow Meter Signal Loss During Service
Display shows E04 and unit remains in service mode without regenerating
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective flow meter sensor, Broken flow meter cable, Incorrect flow meter configuration in controller, Severe scaling in flow meter body
How to Fix / Troubleshooting
Safety: Disconnect power before working on wiring or sensors.
- Check wiring: Trace the cable from the flow meter on the Idrobase valve body to the control board. Ensure the connector is fully seated and wires are not cut or pinched.
- Clean flow meter: Shut off water and relieve pressure. Remove the flow meter cartridge or body. Inspect the turbine or paddle wheel for scale or debris. Clean with a soft brush and descaling solution. Ensure free rotation.
- Controller settings: Enter the installer menu (refer to Idrobase manual) and verify the correct flow meter type and pulse value are selected. Incorrect settings can trigger E04.
- Signal test: With power off, disconnect the flow meter and measure resistance across the sensor (for reed or Hall types). Compare to specification. If open or shorted, replace the flow meter.
- Final check: Reassemble, restore water and power, and run water through a tap. Confirm that the display shows flow or counts down capacity. If not, replace the flow meter assembly.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Flow Meter Assembly