E06
Idrobase Resin Tank Pressure / Overpressure Fault

E06 error and display beeps; no water softening occurs

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked outlet, Closed outlet valve, Excessive inlet pressure, Internal valve blockage in service position

How to Fix / Troubleshooting

Safety: Turn off power. Slowly close inlet valve and open a downstream tap to relieve pressure.

  • Check outlet valve: Ensure the outlet or bypass valves on the Idrobase manifold are correctly positioned for service. A closed outlet can cause overpressure.
  • Inspect downstream plumbing: Look for recently installed shutoff valves or filters that may be closed or clogged.
  • Measure inlet pressure: If available, connect a pressure gauge to the inlet. Verify that pressure is within Idrobase specifications. Install a pressure reducer if pressure is too high.
  • Internal valve check: If overpressure recurs, the service position in the control valve may be partially blocked by resin or debris. Remove and inspect the main piston/rotor and distributor screen. Clean and reassemble.
  • Test: Restore water and power, then run water through the system. Monitor for normal pressure and absence of E06.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Control Valve Body and Outlet Manifold