E19
Idrobase Salt Level Detection Fault (if equipped)

E19 error and unit indicates low salt condition even when salt is present

Advertisements

Possible Causes

Stuck salt level float, Fouled salt sensor, Broken sensor wiring, Incorrect sensor calibration

How to Fix / Troubleshooting

Safety: Disconnect power. Use care when reaching into the brine tank.

  • Verify salt level: Confirm that there is adequate salt in the brine tank and that it is not bridged above the water level.
  • Inspect salt float/sensor: Locate the salt level float or electronic sensor in the brine tank. Ensure it moves freely and is not buried in hardened salt.
  • Clean sensor: Remove the sensor and clean off salt crusts with warm water. Avoid using sharp tools that could damage the sensor body.
  • Check wiring: Follow the sensor cable to the control board and ensure it is intact and properly connected.
  • Reset alarm: After cleaning and reconnection, reset the E19 alarm. If it returns despite correct salt level, replace the salt level sensor assembly.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Salt Level Sensor / Float Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements