E20
Idrobase Leak Detection / Continuous Flow Fault

E20 error and unit reports leak or continuous flow when no water is used

Advertisements

Possible Causes

Dripping tap or toilet downstream, Faulty flow sensor registering false pulses, Incorrect leak detection threshold, Small leak in plumbing

How to Fix / Troubleshooting

Safety: No internal work is required initially, but disconnect power before handling sensors.

  • Check for actual leaks: Close all taps and appliances. Observe the Idrobase display for flow indication. If flow is shown, inspect the house plumbing for dripping fixtures or running toilets.
  • Adjust leak settings: In the controller menu, review the leak detection sensitivity and time thresholds. Increase the threshold if set too low for the installation.
  • Inspect flow sensor: If no leaks are found, clean and inspect the flow sensor/turbine for sticking or vibration-induced movement.
  • Secure piping: Ensure that the inlet and outlet pipes are firmly supported to reduce vibration that could cause false flow readings.
  • Replace sensor if needed: If E20 persists with no real flow, replace the flow sensor assembly.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Flow Sensor / Leak Detection Assembly
Check Price on Amazon