Idrobase Unintended or Nuisance Regenerations

Softener cycles between service and regeneration unexpectedly during the day

Advertisements

Possible Causes

Incorrect clock or regeneration time, Flow meter miscounting usage, Leak detection triggering forced regen, Installer test mode left active

How to Fix / Troubleshooting

Safety: No special safety beyond normal electrical precautions.

  • Verify clock and regen time: Ensure the regeneration time is set to a night-time hour and that the clock is correct.
  • Check for leaks: Inspect for continuous small flows that may cause the controller to think capacity is exhausted.
  • Flow meter calibration: Confirm that the correct flow meter type and pulse value are programmed.
  • Exit test mode: Make sure the controller is not in a service or test mode that forces frequent regenerations.