Idrobase
Insufficient Salt Usage / Under-Regeneration
Softener uses very little or no salt over time
Advertisements
Possible Causes
Regeneration not occurring, Brine tank empty or bridged, Brine draw failure, Incorrect programming for capacity
How to Fix / Troubleshooting
Safety: Basic checks only; disconnect power if opening valve assemblies.
- Check regeneration history: Review the controller log (if available) to see when the last regenerations occurred.
- Inspect salt level: Ensure salt is present and not forming a hard bridge above the water. Break up any bridge.
- Verify brine draw: Observe a regeneration and confirm that the brine level drops during the brine draw stage.
- Adjust programming: If capacity is set too high, the unit may rarely regenerate. Set realistic capacity based on resin volume and hardness.
Advertisements
Repair Difficulty
Easy
2/5