Possible Causes

Regeneration not occurring, Brine tank empty or bridged, Brine draw failure, Incorrect programming for capacity

How to Fix / Troubleshooting

Safety: Basic checks only; disconnect power if opening valve assemblies.

  • Check regeneration history: Review the controller log (if available) to see when the last regenerations occurred.
  • Inspect salt level: Ensure salt is present and not forming a hard bridge above the water. Break up any bridge.
  • Verify brine draw: Observe a regeneration and confirm that the brine level drops during the brine draw stage.
  • Adjust programming: If capacity is set too high, the unit may rarely regenerate. Set realistic capacity based on resin volume and hardness.