E01
Judo
Inlet Water Supply Fault
Display shows E01 and the Judo water softener does not start regeneration
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Closed or partially closed inlet shutoff valve, Blocked Judo inlet strainer, Defective Judo inlet solenoid valve, Insufficient mains water pressure
How to Fix / Troubleshooting
Safety first: Close the main water supply to the softener and disconnect power before opening any covers. Depressurize by opening a nearby tap.
- Check inlet valve: Verify the house shutoff valve feeding the Judo softener is fully open. Many Judo cabinets have a bypass/inlet lever – ensure it is in the correct Service position, not Bypass or Closed.
- Inspect inlet strainer: Judo softeners typically have a fine mesh strainer at the inlet union. Close inlet/outlet valves, unscrew the union, and carefully remove and rinse the strainer under running water. Remove rust, sand, or limescale deposits.
- Check mains pressure: If you have a pressure gauge, confirm at least the minimum pressure specified in the Judo manual (often around 1.5–2.0 bar). Low pressure can prevent the valve from operating correctly.
- Test inlet solenoid valve: Restore power, initiate a manual regeneration, and listen/feel for the inlet solenoid clicking. If there is no sound and the control board is sending power, the solenoid coil may be open or stuck. Replace the Judo inlet solenoid valve assembly if it does not open when energized.
- Reset error: After correcting the issue, power-cycle the unit or use the control panel reset procedure from the Judo manual to clear E01.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Judo inlet solenoid valve
Check Price on Amazon