Possible Causes
Loose low-voltage connector, Failing Judo power adapter, Internal display PCB fault, Moisture ingress into control head
How to Fix / Troubleshooting
Safety first: Unplug the adapter before opening the control housing.
- Check adapter output: Test the Judo power adapter with a multimeter. Replace if voltage is outside the specified range.
- Inspect connectors: Open the control head and reseat the power and display connectors. Look for corrosion or moisture.
- Dry moisture: If condensation is present, gently dry the area and improve ventilation around the unit.
- Replace display module: If power is present at the board but the display remains blank, replace the Judo display module.