Possible Causes
High mains pressure without pressure reducer, Rapid closing Judo valve ports, Loose piping near softener, Missing or failed water hammer arrestor
How to Fix / Troubleshooting
Safety first: Do not touch moving valve parts during regeneration. Avoid standing directly over rigid copper lines when testing.
- Check pressure: Measure mains pressure. If it exceeds Judo's recommended maximum, install or service a Judo pressure reducing valve upstream.
- Secure piping: Ensure all pipes near the softener are properly clipped and supported to reduce movement.
- Install hammer arrestor: Fit a water hammer arrestor on the line feeding the softener if hammer persists.
- Adjust regeneration time: Schedule regeneration for night hours to minimize disturbance, but still address the underlying pressure issue.