Judo Regeneration Scheduling / Timer Fault

Judo water softener does not start regeneration at the programmed time

Advertisements

Possible Causes

Incorrect time-of-day setting, Regeneration mode set to manual only, Inadequate water usage to trigger meter-initiated regeneration, Control board clock malfunction

How to Fix / Troubleshooting

Safety first: No internal work required for basic checks; keep covers closed.

  • Check current time: Enter the user menu and verify the displayed time matches actual time. Adjust if necessary.
  • Review regeneration mode: Ensure the Judo softener is set to metered or time-clock mode as desired. In manual mode, it will never regenerate automatically.
  • Confirm regeneration time: Verify the programmed regeneration start time (e.g., 2:00 AM) and that the unit is not in vacation or standby mode.
  • Check water usage: For metered models, ensure the flow meter is counting usage. If the display never shows flow, see the flow sensor fault section.
  • Manual test: Start a manual regeneration. If this works but automatic cycles never start despite correct settings, the Judo main control board may have a timer fault and require replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Judo main control board
Check Price on Amazon

We may earn a commission from links on this page.