Err 07
Kenmore Bypass / Valve Position Error

Display shows “Err 07” and unit remains in bypass or service mode only

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Internal valve rotor not reaching service position, Debris blocking valve ports, Damaged rotor seal and spacer stack, Control board misinterpreting position

How to Fix / Troubleshooting

Safety first: Disconnect power and shut off water. Place the external bypass in bypass mode before opening the valve head.

Step-by-step checks:

  • 1. Inspect valve rotor and seals:
    • Remove the top cover and then the valve cover screws.
    • Carefully pull out the rotor and seal/spacer stack.
    • Inspect for tears, warping, or heavy iron buildup on the rotor and seals.
    • Clean all parts with warm water and a soft brush.
  • 2. Check for obstructions:
    • Look into the valve body for debris, resin beads, or scale blocking the ports.
    • Flush with clean water if needed.
  • 3. Reassemble correctly:
    • Reinstall the seal and spacer stack in the correct order and orientation.
    • Lubricate seals lightly with silicone-based lubricant approved for water softeners.
    • Reinstall the rotor and valve cover.
  • 4. Test operation:
    • Restore water and power, take the unit out of bypass, and start a manual regeneration.
    • If Err 07 persists, the rotor and seal kit or control board may need replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Rotor and Seal Kit
Check Price on Amazon

We may earn a commission from links on this page.