Err br
Kenmore Brine Refill / Float Fault

Display shows a brine-related error code and unit aborts regeneration

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck brine float, Clogged brine refill port, Leaking brine line fittings, Faulty brine valve

How to Fix / Troubleshooting

Safety first: Unplug the softener and shut off water. Place the unit in bypass.

Step-by-step checks:

  • 1. Inspect brine float:
    • Remove the brine well cover and lift out the float assembly.
    • Check for salt buildup preventing free movement.
    • Clean with warm water and ensure the float moves smoothly.
  • 2. Check brine refill port:
    • Inspect the brine valve and refill port on the valve head for debris.
    • Clean or replace the brine valve assembly if clogged or damaged.
  • 3. Inspect brine line:
    • Check for leaks or loose fittings at both ends of the brine line.
    • Replace cracked or brittle tubing.
  • 4. Test regeneration:
    • Reassemble, restore water and power, and run a manual regeneration.
    • If the error persists, replace the brine valve assembly or control board as indicated by further diagnostics.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Brine Float Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements