Kenmore Demand Initiation or Timer Failure

Softener does not regenerate automatically; only works when started manually

Advertisements

Possible Causes

Flow meter not registering usage, Incorrect regeneration mode setting, Failed control board timer function

How to Fix / Troubleshooting

Safety first: No high-voltage work is required for initial checks.

Step-by-step checks:

  • 1. Check regeneration mode:
    • Ensure the unit is set to demand-initiated regeneration (if desired) and not manual-only.
  • 2. Flow meter:
    • Verify the turbine / flow meter is working by checking for flow indication on the display when water is used.
    • Clean or replace the turbine / flow meter assembly if not registering.
  • 3. Timer function:
    • If on time-clock mode, verify the clock and regeneration time are set correctly.
    • If the unit still does not start automatically, replace the electronic control board.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Turbine / Flow Meter Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements