E17
Lindsay
False Low Salt Indication
E17 error and unit indicates low salt even when tank is adequately filled
Advertisements
Possible Causes
Salt sensor out of position, Sensor coated with sludge or iron, Faulty salt probe, Control board misinterpreting sensor signal
How to Fix / Troubleshooting
Safety first: Unplug the softener before adjusting the sensor.
- Verify sensor mounting: Ensure the Lindsay salt sensor is mounted at the correct height and angle per the manual. If it has slipped down, it may always read low.
- Clean around sensor: Remove any mushy salt or sludge around the sensor. Rinse the sensor tip with clean water and dry.
- Reset alarm: Clear the low salt alarm in the menu and monitor. If it returns immediately, the sensor may be defective.
- Bypass sensor (temporary): Some models allow disabling the salt sensor in programming. This can be used temporarily until a replacement sensor is installed.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Lindsay salt level sensor
Check Price on Amazon