E9
Lindsay
Low Voltage / Power Supply Fault
E9 error and display is blank or flickering, unit intermittently shuts off
Advertisements
Possible Causes
Failed Lindsay power transformer, Loose low-voltage connector, Shorted control board component, Incorrect replacement adapter used
How to Fix / Troubleshooting
Safety first: Unplug the transformer from the wall before handling any wiring.
- Check outlet and adapter: Plug a lamp or tester into the same outlet to confirm power. Inspect the Lindsay transformer label and ensure the correct voltage and amperage are used.
- Inspect low-voltage plug: Verify the low-voltage plug from the transformer is fully inserted into the control head and not corroded or damaged.
- Test transformer output: Using a multimeter set to AC, measure the output voltage of the transformer (typically 24 VAC; confirm on label). If no or low voltage is present, replace the transformer.
- Board inspection: If the transformer is good, remove the control cover and look for burnt components or a burnt smell on the board. If present, the board must be replaced.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Lindsay 24VAC power transformer
Check Price on Amazon