E9
Lindsay Low Voltage / Power Supply Fault

E9 error and display is blank or flickering, unit intermittently shuts off

Advertisements

Possible Causes

Failed Lindsay power transformer, Loose low-voltage connector, Shorted control board component, Incorrect replacement adapter used

How to Fix / Troubleshooting

Safety first: Unplug the transformer from the wall before handling any wiring.

  • Check outlet and adapter: Plug a lamp or tester into the same outlet to confirm power. Inspect the Lindsay transformer label and ensure the correct voltage and amperage are used.
  • Inspect low-voltage plug: Verify the low-voltage plug from the transformer is fully inserted into the control head and not corroded or damaged.
  • Test transformer output: Using a multimeter set to AC, measure the output voltage of the transformer (typically 24 VAC; confirm on label). If no or low voltage is present, replace the transformer.
  • Board inspection: If the transformer is good, remove the control cover and look for burnt components or a burnt smell on the board. If present, the board must be replaced.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Lindsay 24VAC power transformer
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements