Marlo Aggressive Backwash / Media Bed Disturbance

Softener mineral tank makes a roaring or churning noise during backwash

Advertisements

Possible Causes

Backwash flow rate too high, Incorrect drain flow control, Oversized drain line, High inlet pressure

How to Fix / Troubleshooting

Safety first: Noise alone is not dangerous, but ensure drain lines are secure to prevent movement.

Step-by-step checks:

  • 1. Confirm drain flow control size: Verify that the installed Marlo drain flow control button matches the resin tank size and model specifications.
  • 2. Measure backwash flow: During backwash, capture drain water in a bucket for a timed interval to estimate gpm. Compare to Marlo's recommended rate.
  • 3. Check pressure: High inlet pressure can increase backwash intensity. Install or adjust a pressure reducing valve if needed.

When to replace parts: If backwash flow is excessive, replace the Marlo drain flow control with the correct size for your tank.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Marlo drain flow control
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements