Err 07
Morton Power / Memory Retention Fault

“Err 07” appears and the unit may regenerate at incorrect times or not at all; time-of-day may reset unexpectedly.

Advertisements

Possible Causes

Weak internal backup capacitor or battery on control board, Intermittent power supply, Loose power cord connection, Faulty control board memory circuit

How to Fix / Troubleshooting

Safety first: Disconnect power before removing the control panel.

  • Verify power source: Confirm the outlet supplying the Morton softener is delivering stable 120V AC (in North America) and is not controlled by a wall switch or GFCI that frequently trips.
  • Inspect power cord and transformer: Check the power transformer and cord for damage, loose plugs, or overheating. Replace the transformer if it is warm with no load or shows signs of failure.
  • Check control board connections: Remove the control panel and ensure the low-voltage connector from the transformer is firmly seated on the board.
  • Reprogram and monitor: Plug the unit back in, set the correct time and hardness, and observe over 24–48 hours. If the time resets or Err 07 reappears without power loss, the board’s memory/backup circuit is likely failing.
  • Replace control board: Install a new electronic control board compatible with your Morton model. Transfer any jumper settings or programming as specified in the service manual.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Power Transformer
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements