Err 08
Morton Regeneration Initiation / Keypad Fault

Display shows “Err 08” and the softener will not initiate a manual regeneration when the button is pressed.

Advertisements

Possible Causes

Defective REGEN button on keypad, Keypad membrane damage, Control board input failure, Stuck regeneration inhibit setting

How to Fix / Troubleshooting

Safety first: Unplug the softener before working on the control panel.

  • Check programming: Verify that the Morton softener is not set to a mode that inhibits manual regeneration (consult the user manual for your specific model). Clear any lockout or vacation mode.
  • Test other buttons: If only the REGEN button fails but other buttons work, the keypad membrane may be partially failed. If multiple buttons fail, the entire keypad or board is suspect.
  • Inspect keypad and board: Remove the control panel and look for moisture, corrosion, or physical damage around the keypad area. Ensure the ribbon cable is fully seated.
  • Replace keypad/board: On many Morton units, the keypad and display are integrated with the control board. Replace the control panel assembly if the REGEN button remains unresponsive after reseating connections.
  • Manual regeneration workaround: Until repaired, you can often force a regeneration by temporarily adjusting the hardness or capacity settings to trigger an immediate regen, but this is model-dependent and should be done according to the service manual.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Control Panel Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements