Under‑Regeneration / No Trigger
Softener never regenerates, even after long periods of water use
Advertisements
Possible Causes
Flow meter not registering usage, Regeneration mode set to manual only, Day override disabled or set too high, Control board logic fault
How to Fix / Troubleshooting
Safety first: No internal disassembly required for basic checks.
- Check regeneration mode: Ensure the Nobel control is set to metered or time‑clock mode, not manual‑only. Adjust in the installer menu.
- Verify flow registration: Run water at a tap and confirm that the display shows flow or that the usage counter increases. If not, troubleshoot the flow meter.
- Set day override: Configure a maximum number of days between regenerations (e.g., 7 days) so the unit will regenerate even with low usage.
- Manual regeneration: Perform a manual regeneration to restore softening capacity while you diagnose the automatic trigger issue.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Flow Meter Sensor
Check Price on Amazon