Err01
North Star
Turbine / Flow Sensor Signal Fault
Control panel displays Err01 and regeneration will not start
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective turbine/flow sensor, Turbine wheel jammed with debris, Broken turbine cable or connector, Control board flow-sensor input failure
How to Fix / Troubleshooting
Safety first: Unplug the North Star softener from power before opening the cabinet. Turn off the inlet water and use the bypass valve to isolate the softener.
Steps to check and correct:
- 1. Inspect the turbine/flow sensor: Remove the top cover. Locate the turbine/flow sensor assembly in the valve body (usually on the outlet side). Check for sand, iron sludge, or plastic shavings jamming the turbine wheel. Clean gently with a soft brush and water.
- 2. Check wiring: Follow the small low‑voltage cable from the turbine sensor to the control board. Ensure the plug is fully seated and there are no broken or corroded pins. Reseat the connector.
- 3. Spin test: With water supply briefly turned on (still in bypass), observe if the turbine spins freely. If it binds or does not move, the turbine/flow sensor assembly should be replaced.
- 4. Reset the control: Restore power, take the unit out of bypass, and initiate a manual regeneration. If Err01 returns immediately, the sensor or control board is likely defective.
- 5. Replace parts as needed: If cleaning and wiring checks do not clear the error, replace the turbine/flow sensor assembly. If a new sensor does not resolve the issue, the electronic control board may need replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Turbine / Flow Sensor Assembly
Check Price on Amazon