Err02
North Star Meter / Turbine Calibration or No Flow Detected

Display shows Err02 and unit does not meter water usage correctly

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect meter setting in control, Damaged turbine magnet, Incorrect turbine orientation, Control board metering circuit failure

How to Fix / Troubleshooting

Safety: Disconnect power before removing covers. Use bypass to isolate the softener from household plumbing.

  • 1. Verify programming: Enter the installer menu on the North Star control and confirm the correct meter size / turbine type is selected per the model label. Incorrect settings can trigger Err02.
  • 2. Inspect turbine magnet: Remove the turbine from the valve body. Check that the embedded magnet is intact and not cracked or missing. Replace the turbine if the magnet is damaged.
  • 3. Confirm orientation: Ensure the turbine is installed in the correct direction (arrow on housing aligned with water flow). An inverted turbine can cause no-flow detection.
  • 4. Test operation: Restore water and power, then run a faucet. Watch the display for flow indication (gallons or liters counting). If the display does not change, the metering circuit or sensor is faulty.
  • 5. Replace components: If reprogramming and turbine replacement do not clear Err02, replace the turbine/flow sensor assembly. Persistent failure may require a new electronic control board.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Turbine / Flow Sensor Assembly
Check Price on Amazon