Err16
North Star False Continuous Flow / Leak Alarm

Err16 displayed, unit indicates high flow or leak alarm when no fixtures are open

Advertisements

Possible Causes

Turbine/flow sensor misreading, Water hammer or pressure fluctuations, Small plumbing leak downstream, Control board sensitivity issue

How to Fix / Troubleshooting

Safety: Ensure the area is dry and safe. No internal electrical work should be done with wet hands.

  • 1. Confirm actual flow: Check the drain line and listen for water movement. Verify that no toilets are running and no fixtures are dripping.
  • 2. Inspect turbine: Remove and clean the turbine/flow sensor. Debris can cause false pulses.
  • 3. Check plumbing for leaks: Inspect visible piping and fixtures downstream of the softener for slow leaks that could trigger the alarm.
  • 4. Reset alarm: Clear the alarm through the control menu and monitor. If it recurs with no real flow, replace the turbine/flow sensor assembly.
  • 5. Control replacement: If a new sensor does not resolve false alarms, the electronic control board may require replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Turbine / Flow Sensor Assembly
Check Price on Amazon

We may earn a commission from links on this page.