E01
Tier1 Regeneration Start Inhibit / Control Lock Fault

Control panel powers on but unit will not start a regeneration cycle; pressing REGEN does nothing.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Control board logic fault, Defective REGEN button on user interface, Stuck control lock function, Low-voltage power supply instability

How to Fix / Troubleshooting

Safety first: Unplug the Tier1 water softener from power before removing any covers. Water softeners operate with low voltage internally but are connected to mains power.

  • Check for control lock: Some Tier1 electronic heads support a lock function. Press and hold the REGEN button for 5–10 seconds (or REGEN + UP arrow together, depending on model) to toggle the lock. Try starting a manual regeneration again.
  • Power cycle the control: Unplug the power supply for 5 minutes, then plug it back in. Wait for the display to fully boot, then press and hold REGEN for 3–5 seconds to initiate an immediate regeneration.
  • Inspect the power supply: Verify the Tier1 wall transformer is firmly plugged into the outlet and the control head. Use a multimeter to confirm the output (typically 12–24 VAC as labeled on the transformer). Replace the transformer if voltage is missing or unstable.
  • Check the keypad: With power disconnected, gently press each button several times to free any stuck contacts. If some buttons feel mushy or unresponsive and the unit still will not start a cycle, the user interface membrane or main control board is likely defective.
  • Factory reset (if supported): Enter the installer menu (usually by holding SET and UP for several seconds). Navigate to RESET or RESTORE DEFAULTS and confirm. Reprogram hardness, time, and capacity, then test a manual regeneration.

If the softener still will not start a regeneration after these steps, the control board assembly should be replaced.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Tier1 electronic control board / timer assembly
Check Price on Amazon