Tier1 No Automatic Regeneration

Tier1 softener does not regenerate automatically; only regenerates when manually started.

Advertisements

Possible Causes

Incorrect time of day, Regeneration mode set to manual only, Flow meter not counting usage, Power interruptions resetting clock

How to Fix / Troubleshooting

Safety first: No special hazards for programming; avoid opening live electrical components.

  • Set correct time: Ensure the time of day is set correctly and that the regeneration time (e.g., 2:00 AM) is in the future relative to current time.
  • Check regen mode: In the installer menu, verify the unit is set to metered/demand or time clock mode as desired, not manual-only.
  • Verify flow meter: Run water and confirm the display shows flow and remaining capacity decreasing. If not, troubleshoot the flow meter / turbine.
  • Monitor for power loss: If frequent outages occur, consider using a small UPS or ensure the control board retains settings properly. Replace the board if it frequently loses time.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Tier1 flow meter / turbine assembly