ERR5
US Water Systems
Control Board / Memory Fault
US Water Systems softener shows ERR5 and will not accept new settings or loses time frequently
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed control board memory, Power surge damage, Low-voltage transformer issue, Corroded board connectors
How to Fix / Troubleshooting
Safety: Unplug the transformer from the wall before working on the control head.
- Power cycle: Disconnect power for 5 minutes, then reconnect. Sometimes a temporary memory error can be cleared by a full reset.
- Check transformer output: Use a multimeter to verify the transformer is providing the correct AC voltage (commonly 24 VAC) to the control head. Replace the transformer if voltage is low or unstable.
- Inspect the board: Remove the control cover and inspect the circuit board for burn marks, swollen components, or corrosion around connectors. Reseat all plug-in connectors.
- Factory reset: If supported by your specific US Water Systems controller, perform a factory reset following the manual. Re-enter hardness, capacity, and regeneration settings.
- Replace control board: If ERR5 persists after reset and power checks, replace the control board with the correct US Water Systems replacement for your valve model.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Electronic Control Board
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements