E7
Whirlpool
Demand Signal or Capacity Calculation Error
Display shows E7 and unit skips regeneration cycles
Advertisements
Possible Causes
Incorrect capacity or hardness settings, Flow meter not registering usage, Control board calculation fault, Programming set to vacation or off mode
How to Fix / Troubleshooting
Safety first: No plumbing work is required for programming checks; unplug before opening the control housing.
Steps to check:
- 1. Verify programming mode: Ensure the softener is set to demand-initiated regeneration (if applicable) and not in vacation or manual-only mode.
- 2. Check hardness and capacity: Confirm hardness and resin capacity are set correctly per Whirlpool manual. Incorrect values can delay regeneration too long.
- 3. Confirm flow meter operation: Run water and verify that the display shows flow or that gallons remaining decrease. If not, troubleshoot the turbine sensor.
- 4. Reset and monitor: Perform a manual regeneration, then monitor usage and regeneration behavior over several days.
When to call a technician: If E7 persists and all settings and sensors are correct, the control board may need replacement.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Electronic Control Board
Check Price on Amazon
We may earn a commission from links on this page.