AEG Single-Zone Cooling Circuit or Airflow Fault

Dual-zone wine cooler: one zone cools normally, the other is warm, no error code

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed evaporator fan for one zone, Blocked air duct, Faulty zone temperature sensor, Zone damper stuck closed

How to Fix / Troubleshooting

Safety: Unplug before accessing internal panels.

Steps:

  • 1. Compare zones: Note which zone is affected (upper or lower).
  • 2. Listen for fan: With the unit running, listen near the partition. If you do not hear airflow in the warm zone, the fan or damper may be faulty.
  • 3. Access fan/duct: Remove the interior panel of the warm zone to inspect the fan and air duct. Clear any obstructions.
  • 4. Test fan motor: Measure resistance and replace the fan if open or seized.
  • 5. Sensor check: Test the zone's temperature sensor and replace if defective.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Zone Evaporator Fan Motor
Check Price on Amazon