E17
AEG Secondary Zone Temperature Sensor Fault

E17 displayed, dual-zone AEG wine cooler shows error on one zone, that zone not cooling correctly

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed NTC sensor in upper or lower zone, Wiring harness damage between zones, Loose connector at zone interface board, Faulty zone control circuitry

How to Fix / Troubleshooting

Safety: Unplug the unit before removing internal panels.

Steps:

  • 1. Identify affected zone: Determine whether the upper or lower zone is showing E17 and not cooling properly.
  • 2. Locate zone sensor: Each zone has its own cabinet sensor, usually behind a small cover on the side or rear wall of that zone.
  • 3. Inspect and test sensor: Remove the cover, check the sensor and wiring, and test resistance with a multimeter. Replace if open or shorted.
  • 4. Check inter-zone harness: On dual-zone models, a harness often runs between zones or to a central board. Inspect for pinched or damaged wires.
  • 5. Replace sensor or harness: Fit the correct AEG zone temperature sensor or harness as needed.
  • 6. Control board: If sensors and wiring are good, the zone control circuit on the main board may be faulty and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Zone Temperature Sensor (NTC)