AEG Reduced Cooling Capacity / Partial Refrigerant Loss

Wine cooler runs but does not get cold enough, temperature stabilizes above setpoint without error code

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Low refrigerant charge due to micro-leak, Partially blocked capillary tube, Weak compressor, Dirty condenser coil reducing heat rejection

How to Fix / Troubleshooting

Safety: Do not attempt to open the sealed refrigeration system. Only certified technicians may handle refrigerant.

User-level checks:

  • 1. Verify load and usage: Avoid loading many warm bottles at once. Allow 24 hours for temperature to stabilize after loading.
  • 2. Check door seal: Inspect the gasket for gaps or damage. Close the door on a sheet of paper; if it pulls out easily, the seal may be weak. Replace if necessary.
  • 3. Clean condenser: Unplug the unit, remove the rear panel, and gently clean dust from the condenser coil.
  • 4. Ambient temperature: Ensure the cooler is installed within the specified ambient range. Very hot rooms reduce performance.
  • 5. Feel temperature gradient: Carefully touch the condenser and compressor after running for 15–20 minutes (they should be warm/hot). If they are running but the cabinet remains warm, a sealed system issue is likely and requires professional service.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor
Check Price on Amazon