Amana Single-zone cooling failure in dual-zone system

Dual-zone Amana wine cooler: one zone cools properly while the other is too warm

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed evaporator fan for one zone, Air damper stuck closed, Separate thermistor failure in warm zone, Control board channel failure for that zone

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing internal panels.

  • Identify affected zone: Determine whether the upper or lower zone is not cooling.
  • Check fan operation: Open the door and listen for airflow in each zone. If one zone's fan is silent, access that zone's evaporator fan and test/replace it.
  • Inspect air damper (if equipped): Some dual-zone models use dampers to share cooling. Ensure the damper for the warm zone is not stuck closed or blocked.
  • Test zone thermistor: Measure resistance of the thermistor for the warm zone and compare to spec. Replace if out of range.
  • Control board evaluation: If hardware is good but one zone still does not cool, the control board's output for that zone may be faulty and require replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Evaporator Fan Motor (Zone-Specific)
Check Price on Amazon

We may earn a commission from links on this page.