Amana
Loss of independent zone control
Dual-zone Amana wine cooler: temperatures of both zones are the same despite different setpoints
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed zone divider insulation, Air damper stuck open, Thermistors cross-wired or failed, Control board not regulating zones separately
How to Fix / Troubleshooting
Safety: Unplug the unit before removing interior panels.
- Verify setpoints: Confirm that the two zones are set to different temperatures on the display.
- Inspect divider and seals: Check the physical divider between zones and any gaskets or seals for damage that would allow free air mixing.
- Check dampers: If the model uses dampers, ensure they are not stuck open, allowing full air exchange between zones.
- Test thermistors: Verify each zone's thermistor reads correctly. Replace any that are out of spec.
- Control board replacement: If mechanical separation is intact and sensors are good, the main control board may have lost independent control of the zones and should be replaced.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Zone Divider / Air Damper Assembly
Check Price on Amazon
We may earn a commission from links on this page.