Amana No power condition

Wine cooler will not turn on at all; no lights, no display, no sound

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Tripped circuit breaker or GFCI, Faulty outlet, Damaged power cord, Internal fuse blown on control board, Failed main control board

How to Fix / Troubleshooting

Safety: Use caution when working with household electrical circuits. Unplug the unit before opening any panels.

  • Check household power: Test the outlet with another device. Reset any tripped breakers or GFCI outlets.
  • Inspect power cord: Look for cuts, frays, or burn marks. If damaged, replace the cord with an Amana-approved replacement.
  • Verify plug connection: Ensure the plug is fully inserted into the outlet and not loose.
  • Check internal fuse: Remove the rear access panel and inspect the main control board for a fuse. Test it with a multimeter and replace if blown, using the exact same rating.
  • Board replacement: If the fuse is good but there is still no power to the display or lights, the main control board may have failed and should be replaced.