Antarctic Star Display Power or PCB Failure

Display is completely blank but the interior light may still work.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose display power connector, Failed display PCB, Faulty low-voltage power supply on main board, Broken wiring harness

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing electronics.

  • Check power: Confirm the cooler is receiving power and the interior light works when the door opens.
  • Inspect display connections: Remove the control panel and verify the display board connector is firmly attached.
  • Check main board output: At the main control PCB, ensure the low-voltage output to the display is present (requires a multimeter and electrical knowledge).
  • Replace display board: If the main board supplies correct voltage but the display remains blank, replace the display PCB.
  • Replace main board: If no low-voltage output is present, replace the main control PCB.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Display PCB
Check Price on Amazon

We may earn a commission from links on this page.