Temperature Calibration / Sensor Drift
Temperature display is inaccurate compared to an actual thermometer inside the cabinet.
Advertisements
Possible Causes
Aging thermistor, Sensor not in correct airflow path, Control board calibration drift, Sensor partially detached from wall
How to Fix / Troubleshooting
Safety: Unplug the cooler before adjusting or replacing sensors.
- Verify with a reliable thermometer: Place a calibrated thermometer in the center of the cabinet away from walls and compare readings after several hours.
- Check sensor mounting: Ensure the cabinet temperature sensor is firmly attached to the wall or bracket and not touching the evaporator coil.
- Replace thermistor: If the display is consistently off by more than a few degrees, replace the cabinet thermistor.
- Control board: If a new sensor does not correct the discrepancy, the main control PCB may have calibration issues and require replacement.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Cabinet Temperature Sensor (Thermistor)