Antarctic Star
Compressor Power or Control Failure
Wine cooler not cooling; fans run but compressor is silent and cold to the touch.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty main control PCB relay, Broken wire to compressor, Open thermal overload, Defective temperature control logic
How to Fix / Troubleshooting
Safety: Unplug the cooler before testing wiring or removing panels.
- Check temperature setting: Ensure the setpoint is low enough to call for cooling.
- Access control board: Remove the rear cover to access the main control PCB. Look for burnt components or loose connectors.
- Inspect compressor wiring: Trace the wires from the control board to the compressor start relay and overload. Repair any broken or burnt wires.
- Test compressor voltage: With extreme caution and proper tools, a qualified person can measure AC voltage at the compressor input when cooling is demanded. If no voltage is present, the control board relay is likely faulty.
- Replace control board: If wiring is intact and the board does not send power to the compressor, replace the main control PCB.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control PCB
Check Price on Amazon