Aobosi Single-Zone Cooling Imbalance

Dual-zone Aobosi wine cooler: one zone cools properly while the other is too warm or too cold.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Zone-specific temperature sensor failure, Stuck air damper between zones, Faulty zone control relay on PCB, Blocked airflow vents between zones

How to Fix / Troubleshooting

Safety: Unplug the unit before removing interior panels between zones.

  • Compare readings: Use thermometers in both zones to verify actual temperatures versus display.
  • Check vents: Ensure that air vents between zones are not blocked by shelves or bottles.
  • Inspect zone sensor: Locate and test the NTC sensor for the affected zone as described in sensor-related procedures. Replace if readings are incorrect.
  • Air damper (if equipped): Some models use a motorized damper to share cooling. Check that the damper moves freely and is not stuck closed or open. Replace the damper motor if it does not actuate.
  • Control board: If hardware is fine but one zone still does not regulate, the zone control circuit on the main PCB may be faulty and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Zone Temperature Sensor or Air Damper Assembly
Check Price on Amazon

We may earn a commission from links on this page.